COMITRONIC AWAX 26 XXL
RM 970.00
- Time before dangerous failure: MTTFd = 415 years
- Cycle before dangerous failure: B10d=100,000 at 5A
- Risk duration: 20 ms max.
- Cable severing protection: yes (opening of safety lines)
- Short-circuit and overload protection: yes, using DLC (opening of safety lines and current limiting in contacts)
- Reaction 2 µs ultrafast
- Indicators: 3 LEDs for diagnostics
- Reset: configurable by dip-switch (SR=Automatic, N=manual)
- Mounting: symmetrical DIN 35mm rail on DIN 50022
- Mounting: IP 20 electrical box
- Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum
- Temperature: -20°C to +60°C
- Certification: TÜV Rheinland 01/205/5168/11
- UL 508 / C22.2 no.14 C-UL-US listed 34CB (file E214209)