COM3C - TWO-HAND CONTROL EN 574 AND ISO 13849-1
Two-hand control EN 574 and ISO 13849-1
Version for mechanical or touch buttons KOB101T
Controls the position of the press
Removable terminals
 
 
  • Performance level with AWAX controller: PL = e
  • Safety category: IIIC
  • Safety Integrity Level: SIL 3
  • Time before dangerous failure: MTTFd = 190 years
  • Cycle before dangerous failure: B10d=100,000 at 5A
  • Risk duration: 20 ms max.
  • Cable severing protection: yes (opening of safety lines)
  • Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V parallel redundant
  • Indicators: 3 LEDs for diagnostics
  • Reset: automatic with simultaneity control at 400 ms
  • Position control: high press position contact input
  • Mounting: symmetrical DIN 35mm rail on DIN 50022
  • Mounting: IP 20 electrical box
  • Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum
  • Temperature: -20°C to +40°C
  • Certification: INERIS 0080.5486.520.04.12.0059
 